Transformer Radiator Leak Sealing
Weeping transformer radiator headers and seams sealed and rebuilt with an oil-tolerant composite, then coated to keep the corrosion from spreading.

The challenge
A transformer radiator bank was weeping oil from corrosion pinholes along the fin headers and the welded seams. The seep left oil stains running down the radiators and a slow loss that maintenance kept chasing from one spot to the next. Weeping oil from a transformer is more than a housekeeping problem. It signals that the steel is thinning, it can spread to the next seam as the pinholing works along the header, and the staining and drips raise both an environmental and a reliability concern for the unit. Draining and replacing radiators is costly and pulls the transformer out of service, so the bank needed a repair that worked on the wetted steel and held.
Our approach
We work on the wetted steel rather than fighting it. First we clean the weeping area and stop the active seep so the surface can hold a repair. Then we rebuild the corroded header and the affected seams with an oil-tolerant composite that bonds to oil-contaminated steel, returning a sound profile where the pinholes were. Once the leak is sealed and the metal is rebuilt, we carry a corrosion coating across the radiator surfaces so the pinholing does not simply march on to the next seam. The result seals the leak and protects the bank without draining the radiators and swapping them out.
- Assess the bankWe trace the weeping pinholes along the fin headers and seams and confirm where the steel has thinned so the repair covers the active loss, not just the surface stain.
- Surface preparationWe clean the oily, weeping area and prepare the wetted steel so the composite has a sound surface to grip on the contaminated metal.
- Stop the seep and rebuildWe stop the active seep, then rebuild the corroded header and seams with an oil-tolerant composite that bonds to the wetted steel and returns the lost profile.
- Coat the radiator surfacesWe carry a corrosion coating across the radiator surfaces so the pinholing is held in check and does not spread to the next seam.
- Return to serviceWe let the repair cure and inspect the sealed, coated bank before it goes back into service, with no radiators drained or replaced.
The result
- Weeping oil leak stopped at the corroded headers and seams
- Lost metal rebuilt with an oil-tolerant composite bonded to the wetted steel
- Radiator surfaces coated so the pinholing is held back from the next seam
- Bank sealed and protected without draining and replacing radiators, delivered by factory-trained and factory-certified Belzona applicators